Hydraulic Oil Filtration and Dewatering Tester - Qinsun
Fabricante profesional de instrumentos de prueba
Línea directa nacional de consulta:+86 021-64208466
Productos

Hydraulic Oil Filtration and Dewatering Tester

Evaluates performance of hydraulic oil filters and dewatering systems for removing particles and wat

WhatsApp: +86 13816217984

Email: info@qinsun-lab.com

Contenido

Applications:

Hydraulic and lubrication system oil purification and filtration;

Hydraulic and lubrication system oil degassing;

Hydraulic and lubrication system oil demulsification;

Hydraulic and lubrication system oil dewatering.


Parámetros técnicos:

1. Rated flow rate L/min: 40. 100. 150

2. Rated pressure MPa: 0.6

3. Original pressure loss MPa: ≤0.2

4. Coarse filtration precision μm: 100

5.Primary filtration precision μm: 25. 40

6. Secondary filtration precision μm: 3. 5. 10

7. Motor power Kw: 1.1+0.75. 2.2+1.1. 4+1.1

8.Voltage V: 380

9. Weight Kg: 380. 480. 680

10. External dimensions mmLXBXH: 1500×800×1700. 1800×1000×1800. 2200×1100×180


Technical features:

1. the oil filter includes two motor-driven special gear pumps, with low noise, self-absorption capacity, smooth operation and other characteristics;

2. high-pressure pipeline is equipped with an overflow protection device, which can effectively protect the hydraulic system's Safety;

3. the use of thermal relay protection to prevent motor damage caused by motor overload;

4. suction port coarse filter to protect the oil pump and extend the service life of the fine filter;. 5. the pump is equipped with a two-stage fine filter after the pump to protect the oil pump.

5. Two-stage fine filter is provided after the pump, so that the oil can quickly reach high cleanliness and achieve the required result;

6. The fine filter can be selected with different precision according to the different needs of users to achieve the required result;

7. The panel is equipped with a pressure gauge, which continuously indicates the operating status of the system and the degree of contamination of the filter element during the working time;

8. The adoption of a separate heating system can effectively solve the impact on the life of the filter element in case of a low ambient temperature. The influence on the life of the filter element is effectively solved in the case of low ambient temperature.

屏幕截图 2025-05-08 112103

Descargo de responsabilidad: El contenido anterior es para referencia y comunicación solo entre expertos de la industria, y no garantiza su exactitud o integridad. De acuerdo con las leyes y reglamentos relevantes y los reglamentos de este sitio web, las unidades o individuos que compren artículos relacionados deben obtener cualificaciones y condiciones de cualificación válidas.


Mensaje en línea

Detalles de contacto

Teléfono de la empresa

+86-21-6420 0566

Horas de trabajo

De lunes a viernes

Teléfono móvil:

13816217984

Correo electrónico:

info@qinsun-lab.com