STD-RCF 7 ROLLING CONTACT FATIGUE MACHINE – 10000 rpm - Qinsun
Fabricante profesional de instrumentos de prueba
Línea directa nacional de consulta:+86 021-64208466
Productos

STD-RCF 7 ROLLING CONTACT FATIGUE MACHINE – 10000 rpm

IntroductionThe machine is floor standing and designed to be installed either as a single unit

WhatsApp : +86 13816217984

Email : info@qinsun-lab.com

Contenido

Introducción

The machine is floor standing and designed to be installed either as a single unit or, more cost effectively, as a multi-unit installation, using a common pneumatic loading system, so that the same load is applied to each test station.

Each station incorporates a PLC, with inputs via touch-screen, for independent control of motor speed and test assembly temperature, plus a vibration sensor and adjustable level trigger circuit, for detecting rolling contact fatigue and stopping the motor.

Load actuators are connected in parallel to a common pneumatic supply, with a manually set precision regulator and a pressure transducer calibrated for load measurement. Manual valves are provided to allow individual actuators to be isolated from the pneumatic circuit, hence removing the load from the associated test station.

Each test station has its own, independently controlled, lubricant circulation system.

The machine installation footprint is kept to a minimum. It is simple to operate, so requires minimal training.

Technical Specifications

Test Geometry:Cone on Angular Contact Bearing Adapter (Bearing 7206)

Thrust Ball Bearing on Disc Adapter (Bearing 51208)

Roller Thrust Bearing on Disc Adapter (Bearing 81208 TN)

Back-to-back Bearing Adapter (Bearing 7209 x 2)
Motion:Rotary
Axial Load:200 to 10.000 N
Spindle Bearing Load:10.000 N @ 3.000 rpm

4.000 N @ 10.000 rpm
Speed:200 to 10.000 rpm
Motor:1.0 kW @ 10.000 rpm
Temperature:Ambient to 120°C
Test Stations:Up to 6
Control:PLC
Lubricant Service Module:Included


Manually Controlled Parameters


Load:Pneumatic – actuators in parallel
Rotational Speed:Each test station independently controlled
Temperature:Each test station independently controlled
Vibration Level:Each test station


Data Logged Parameters


Load:Pressure transducer – one per installation
Temperature:Yes – each test station
Test Duration:Yes – each test station


Services


Electricity per Test Station:220/240V, single phase, 50 Hz, 4.5 kW

110/120V, single phase, 60 Hz, 4.5 kW
Clean, dry air:4 cfm at 8 bar (120 psi)


Descargo de responsabilidad: El contenido anterior es para referencia y comunicación solo entre expertos de la industria, y no garantiza su exactitud o integridad. De acuerdo con las leyes y reglamentos relevantes y los reglamentos de este sitio web, las unidades o individuos que compren artículos relacionados deben obtener cualificaciones y condiciones de cualificación válidas.


Mensaje en línea

Detalles de contacto

Teléfono de la empresa

+86-21-6420 0566

Horas de trabajo

De lunes a viernes

Teléfono móvil:

13816217984

Correo electrónico:

info@qinsun-lab.com