ASTM D 92  Cleveland Open Cup Flash Point Tester

Detailed Product DescriptionSTD:Open Cup Flash Point TesterThermometer:(-6 ~ 400)°CFlame Diamet

WhatsApp : +86 13816217984

Email : info@qinsun-lab.com

Contenido

Detailed Product Description

STD:Open Cup Flash Point TesterThermometer:(-6 ~ 400)°C
Flame Diameter:3.2mm ~ 4.8mmAmbient Temperature:(-10∼50)°C
Maximum Power Consumption:650WDimension:350mm×290mm×350mm
Keywords:Cleveland Open Cup Closed-Cup Flash Point Tester
Highlight:

oil analysis equipment

oil testing equipment

Aplicación

Cleveland Open Cup Flash Point Tester is designed and made as per standards GB/T3536-2008 Petroleum Products - Determination of Flash and Fire Points - Cleveland Open Cup Method and ASTM D 92 Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester. It is applicable to all petroleum products with flash points above 79°C and below 400°C except fuel oils.

Características

1. It adopts special heating furnace to ensure the safety of test. The heating power is continuously adjustable. It can meet requirements of test.

2. The instrument adopts desktop structure. The stainless steel working table and furnace shell make it beautiful and elegant.

3. The instrument is fully self-contained complete. The operator can do determination as long as connecting with coal gas or other civil gas.

4. It equipped with flame extinguishing cover which accord with requirements of test.

Specifications

1. Power supply: AC (220±10%) V, 50Hz.

2. Heating device: Quartz tube furnace heating, no naked fire, explosion prevented. The power is adjustable from 0W to 600W.

3. Test flame applicator: It applies the test flame automatically.

4. Thermometer: (-6 ~ 400)°C. It is the same as thermometer ASTM 11C.

5. Igniting device: (1) Ignition source: coal gas(or civil gas)

(2) Flame diameter is 3.2mm ~ 4.8mm

6. Ambient temperature: (-10∼50)°C

7. Relative humidity: ≤85%

8. Maximum power consumption: 650W

9. Dimension: 350mm×290mm×350mm (thermometer is not included)

 Item Unit Qty Remarks
 Oil cup Piece 1
 Ignition Set 1
 Thermometers (-6~400 ℃, scale division is 2 ℃) Piece 1
 Thermometer support Set 1
 5A fuse(∅5×20) Piece 2
 Latex pipe∅6 Meter 1.5 Connecting the inlet port of the instrument
 Gas pipe connecting head Piece 1 Gas pipe and latex tube adapter
 Flameout cover Piece 1

Descargo de responsabilidad: El contenido anterior es para referencia y comunicación solo entre expertos de la industria, y no garantiza su exactitud o integridad. De acuerdo con las leyes y reglamentos relevantes y los reglamentos de este sitio web, las unidades o individuos que compren artículos relacionados deben obtener cualificaciones y condiciones de cualificación válidas.