Name: | Closed Cup Flash Point Tester | Criterios: | ASTM D93. |
---|---|---|---|
Oil Cup Inner Diameter: | 50.7mm~50.8mm. | Oil Cup Depth: | 55.7mm~56.0mm |
The Scribed Line Depth Of Capacity Of Testing Oil: | 33.9mm~34.3mm. | Capacity Of Testing Oil:: | About 70ml |
Thermometers: | Scale 20°C~150°C, Division 1°C. | Keywords: | Oil Analysis Equipment |
Highlight: | oil analysis equipmentoil analysis machine |
1.It adopts LCD screen to display. Full English man-machine dialog interface. It can preset the parameters of expected flash point, sample mark number, atmospheric pressure, test date, etc. It has menu to prompt and input function of guide type.
2.It adopts simulation tracking display the function curve of temperature rising and test time. It has prompt functions of English mis-operation, test date and test time.
3.It is equipped with standard RS-323.485 computer port. The lower computer can save 100 groups of historical data. The test data can be saved for a long time, transmitted and modified if the instrument being connected with computer.
4.It can correct the influence of atmospheric pressure and calculate the correction automatically.
5. Differential detection. Automatically correct the systematic deviation.
6. Automatically open the lid, ignite, detect and print test data. The test arm lifting up and down automatically.
7. It adopts electric ignition to fire light the gas flame. It will light only need to press the button.
8. Humanized design, beautiful and safe. Easy to operate.
1 .Power supply:AC(220±10%)V,50Hz
2. Temperature measurement Range: room temperature~300°C
Repeatability:≤3°C
Reproducibility:≤6°C
Accuracy:0.1°C
3. Heating rate: Procedure A:(5~6)°C/mi
Procedure B:(1~1.6)°C/min
Automatic control and manually adjustable.
4.Stirring rate
(1) Procedure A: (90~120)RPM
(2) Procedure B: (250±10)RPM
Automatic control and manually adjustable.
5.Igniting mode: Electric ignition. Gas flame diameter:3.2mm~4.8mm
6.Working condition: ambient temperature:(10~40)°C
relative humidity:≤80%
7. Maximum power consumption 500W
8. Dimension 520mm×360mm×310mm
1 | Fuente de alimentación | AC(220±10%)V, 50Hz. |
2 | Flash point determination | Range: Ambient to 300℃. Meet requirement of GB/T 261-2008 Meet requirement of GB/T 261-2008 Resulotion: 0.1℃ |
3 | Heating rate | Procedure A: (5~6)℃/min Procedure B: (1~1.5)℃/min |
4 | Stirring rate | Procedure A: (90~120)RPM, Procedure B: (250±10)RPM Automatic control and manually adjustable. |
5 | Igniting mode | Igniting source: gas(or other civilian fuels)Electric ignition. Gas flame diameter: 3.2mm~4.8mm |
6 | Ambient temperature | ≤ 40℃ |
7 | Relative humidity | ≤ 80% |
8 | Maximum power consumption | 500w |
9 | Overall dimension | 410mm×360mm×310mm |
Descargo de responsabilidad: El contenido anterior es para referencia y comunicación solo entre expertos de la industria, y no garantiza su exactitud o integridad. De acuerdo con las leyes y reglamentos relevantes y los reglamentos de este sitio web, las unidades o individuos que compren artículos relacionados deben obtener cualificaciones y condiciones de cualificación válidas.