Catheter Flexibility Tester - Qinsun
Fabricante profesional de instrumentos de prueba
Línea directa nacional de consulta:+86 021-64208466

Medidor de flexibilidad del catéter

Main Uses of the Catheter Flexibility TesterThe catheter flexibility tester is mainly used to evalua

Correo electrónico: info@standard-groups.com

Contenido

Main Uses of the Catheter Flexibility Tester

The catheter flexibility tester is mainly used to evaluate the flexibility and durability of catheters or guidewires during bending or twisting processes. This equipment is widely applied in medical, industrial and other fields to ensure the safety and reliability of catheters during use. In the medical field, it is particularly suitable for evaluating the flexibility and durability of medical catheters such as blood vessel catheters, urinary catheters, and biliary catheters, ensuring that they will not cause harm to patients during use. In the industrial field, it can be used to assess the flexibility of catheters transporting fluids, gases and other media in different environments, ensuring their good performance during use. In addition, in fields such as aviation and automotive, the catheter flexibility tester is also used to evaluate the flexibility and durability of catheters under different temperature and pressure conditions.


Criterios de conformidad

YY/T 1554 - 2017, etc.


Parámetros técnicos

- **Testing Range**:    - **Force Range**: Usually 0 - 10 kilograms or more, specifically depending on the model and specifications of the tester.    - **Testing Stroke**: The strokes in the vertical and horizontal directions may vary. For example, the vertical stroke could be 0 - 300mm, and the horizontal stroke could be 0 - 700mm, etc.    - **Testing Speed**:        - **Press - down Speed**: Usually adjustable within the range of 0 - 300mm/min.        - **Wire - drawing Speed**: Some testers may have a wire - drawing function, with a speed of 0 - 500mm/min or faster. - **Catheter Clamping Method**: Usually, pneumatic clamping or mechanical clamping methods are adopted to ensure the stability and accuracy of the catheter during the testing process. - **Control System**:    - Usually, a PLC control system is adopted, featuring high precision and stability.    - The operation interface may be equipped with a color touch screen, which is convenient for users to make settings and operations.


1741843817426.png

Descargo de responsabilidad: El contenido anterior es para referencia y comunicación solo entre expertos de la industria, y no garantiza su exactitud o integridad. De acuerdo con las leyes y reglamentos relevantes y los reglamentos de este sitio web, las unidades o individuos que compren artículos relacionados deben obtener cualificaciones y condiciones de cualificación válidas.


Mensaje en línea

Detalles de contacto

Teléfono de la empresa

+86-21-6420 0566

Horas de trabajo

De lunes a viernes

Teléfono móvil:

13816217984

Correo electrónico:

info@qinsun-lab.com

Código QR