Non-combustible material refers to the material when it is heated by the fire even if it become the
Correo electrónico: info@standard-groups.com
Non-combustible material refers to the material when it is heated by the fire even if it become the red or melting, which will not occur burning. Non-combustibility tester is designed by the new GB8624-2012 building materials fire classification requirements in the mandatory testing project , But also fully meet the GB / T 5464 and ISO 1182 international standards. Furnace temperature can quickly reach the temperature balance into the test program. The temperature curve is free to print.
Criterios
GB/T 5464 Method for non-combustibility test of building
ISO 1182 Reaction to fire non-combustibility test of building products-non-combustibility test
BS 476-4 Fire tests on building materials and structures-Full-scale room test for surface products
BS 476-11 Method for assessing the heat emission from building materials
ASTM E 136 Standard test method for behavior of materials in a vertical tube furnace at 750℃
Parámetros técnicos
Proyecto | Parámetros |
Tamaño | 500mm x 500mm x 1500mm |
Peso | 50kg |
Poder | 220V, 50Hz, 1500W |
Air flow hood | Φ75 mm×500 mm |
Características
Patented design intelligent test system;
Stainless steel burner, beautiful and easy to clean up;
Heating furnace: Φ95 mm × Φ75 mm × 150 mm;
3 mm × 0.2 m nickel 80% chromium 20% resistance band;
Equipped with airflow hood;
Thermocouple: Insulated nickel-chromium-nickel-aluminum armor Φ3 mm / Φ0.3 mm;
Power controller, control test power;
The experiment began to temperature equilibrium time of about 35min;
Thermometer: 0 ~ 1000 ℃± 5%.
Sistema
High degree of automation, the test process is safe and reliable, easy to operate;
The use of high-quality bar heater, the furnace temperature can rise to 900 ℃;
Programmable controllers (PLCs) automate the heating process by using modern electronic devices, can greatly extend the life of the furnace;
PLC output signal control heating voltage is 0-110VAC. Eliminate the effect of voltage fluctuation on temperature;
PLC added solid state relay to achieve PID control heating;
Built-in new furnace temperature, calibration temperature, the normal test temperature three procedures;
Embedded integrated 7 "touch screen can be set to control the parameters set and display / experimental data acquisition and preservation / screen monitoring / real-time temperature curve display / historical curve and data query;
With sound alarm and alarm accident display function.
Descargo de responsabilidad: El contenido anterior es para referencia y comunicación solo entre expertos de la industria, y no garantiza su exactitud o integridad. De acuerdo con las leyes y reglamentos relevantes y los reglamentos de este sitio web, las unidades o individuos que compren artículos relacionados deben obtener cualificaciones y condiciones de cualificación válidas.
Teléfono de la empresa
+86-21-6420 0566
Horas de trabajo
De lunes a viernes
Teléfono móvil:
13816217984
Correo electrónico:
info@qinsun-lab.com